Power for your business
Electric motors, pumps and special solutions for industrial applications.
View productsManufacturing you can rely on
We manufacture electric motors and pumps with an emphasis on precision, efficiency and solutions tailored to each customer's needs.
Custom manufacturing
We design and build solutions for the specific application, power and operating requirements.
More than 200 variants a year
Every year we produce hundreds of different motor and pump designs for specific customer requirements.
Focus on efficiency
We keep improving the efficiency of our products to reduce the energy consumption of their operation.
Solutions for many industries
Our products are used in industry, water management and other specialised operations.
Precision and inspection
Every product goes through careful manufacturing and inspection with a focus on reliability and long service life.
Development and innovation
We develop new solutions based on market demand and the specific technical requirements of our customers.
Choose from our products
Electric motors, pumps and special solutions for industrial applications and individual technical requirements.
01
Motors
Electric motors for a wide range of industrial applications, in standard and custom designs.
View motors →
02
Pumps
Immersion and industrial pumps designed for reliable operation even in demanding conditions.
View pumps →
03
Special products
Special motors and other solutions developed for specific applications and individual customer requirements.
View solutions →Frequently asked questions
Didn't find the answer to your question? Contact our technical support team.
What does the "IP degree of protection" mean?
The IP rating states how well electrical equipment is protected against the ingress of solid objects and liquids, especially water. It is expressed by the so-called IP code, which consists of the letters “IP” followed by two digits: the first digit indicates protection against solid objects, the second the degree of protection against water (our motors and pumps except for the special submersible motors with IP68 are made with IP54 protection as standard; IP55 is available on request.)
IP54 – dust-protected, protected against splashing water
IP55 – dust-protected, protected against water jets
..
..
IP68 – dust-tight, protected against continuous immersion in water
What does the "insulation class" mean?
The insulation class of electric motors is marked with the letters A, E, B, F and H and states the maximum temperature rise the motor can withstand. Under normal load, motors are designed for an ambient temperature of up to approx. 40 °C, and the motor itself (its winding) withstands its own temperature rise up to the following values:
Insulation class A: maximum winding temperature 105°C (ambient temperature 40 °C, permitted temperature rise 60 °C, thermal reserve 5 °C)
Insulation class E: maximum winding temperature 120°C (ambient temperature 40 °C, permitted temperature rise 75 °C, thermal reserve 5 °C)
Insulation class B: maximum winding temperature 130°C (ambient temperature 40 °C, permitted temperature rise 80 °C, thermal reserve 10 °C)
Insulation class F: maximum winding temperature 155°C (ambient temperature 40 °C, permitted temperature rise 105 °C, thermal reserve 10 °C)
Insulation class H: maximum winding temperature 180°C (ambient temperature 40 °C, permitted temperature rise 125 °C, thermal reserve 15 °C)
As standard, our motors are manufactured with insulation class F, but motors with insulation class H can be made on request.
What duty types "S" are there?
Duty types:
- S1 (continuous running duty): constant load that brings the motor to a constant, steady temperature.
- S2 (short-time duty): constant load for a period shorter than needed to reach a steady motor temperature, followed by switching the motor off
- S3 (intermittent periodic duty) – alternating periods of constant load and rest, during which the motor temperature does not stabilise.
- S4 (intermittent periodic duty with starting)
- S5 (intermittent periodic duty with electric braking)
- S6 (continuous operation periodic duty): alternating periods of constant load and no-load running
- S7 (continuous operation periodic duty with electric braking)
- S8 (continuous operation periodic duty with related load and speed changes)
- S9 (duty with non-periodic load and speed variations)
- S10 (duty with discrete constant loads)
What is the motor wiring diagram?
What mounting arrangements are available?
You can choose from these mounting arrangements for your motor:
B3: foot-mounted motor
B5: flange-mounted motor with a B5 flange (see the individual motor pages for the flange size)
B14: flange-mounted motor with a B14 flange (choose one of two flange sizes: “small or large”; see the individual motor pages for the flange size)
B35: motor mounted on feet + B5 flange (see the individual motor pages for the flange size)
B34: motor mounted on feet + B14 flange (choose one of two flange sizes: “small or large”; see the individual motor pages for the flange size)
What is the standard design of EMP motors?
– without a temperature sensor (on request: Thermik S01 bimetal sensor or KTY84-130 silicon sensor);
– the motors have one earthing terminal located inside the terminal box cover.
Mounting arrangements:
Operating conditions:
– operating environment: normal, cold, humid, wet, dusty (non-flammable dust), under a shelter. Motors for other operating conditions can be built on request;
Where can IE2 and IE3 motors be used?
IE2 motors:
- operation with a frequency inverter
- or motors designed for a duty type other than S1 (continuous running)
- or for export outside the EU
IE3 motors:
What bearings are used in the motors?
TM and JMC series motors:
- motor with shaft height 63– bearing 6202 on the drive end, bearing 6202 on the fan end
- motor with shaft height 71 – bearing 6202 on the drive end, bearing 6202 on the fan end
- motor with shaft height 80 – bearing 6204 on the drive end, bearing 6203 on the fan end
- motor with shaft height 90 – bearing 6205 on the drive end, bearing 6204 on the fan end
- motor with shaft height 100 – bearing 6206 on the drive end, bearing 6206 on the fan end
TMB and JMO series motors:
- motor with shaft height 63– bearing 6202 on the drive end, bearing 6202 on the fan end
- motor with shaft height 71 – bearing 6202 on the drive end, bearing 6202 on the fan end
- motor with shaft height 80 – bearing 6204 on the drive end, bearing 6204 on the fan end
- motor with shaft height 90 – bearing 6205 on the drive end, bearing 6205 on the fan end
- motor with shaft height 100 – bearing 6206 on the drive end, bearing 6206 on the fan end
What are the names of motor spare parts?
Sorry, we are still working on this page. Thank you for your understanding!